MPU-6050 motion sensor
Understand the MPU-6050’s acceleration and angular velocity outputs and check the supply of the chip versus its carrier board.

Measurements
The accelerometer reports acceleration along three axes. A stationary sensor reacts to gravity, so orientation changes which axes report it. The gyroscope measures angular velocity. Integrating angular rate alone introduces orientation drift.
Digital interface
The MPU-6050 host interface is I²C. Identify SDA and SCL from the carrier labels. Connect grounds and use the manufacturer’s supply and logic specifications, rather than assuming every board sold as GY-521 has the same electrical design.
Range selection
Choose the measurement range to fit the expected motion. A narrower range gives finer resolution at the cost of clipping larger motion. Use the documented scale factor for the configuration you actually read.
Specifications
| Parameter | Value or condition | Source |
|---|---|---|
| Bare chip VDD | 2.375–3.46 V | TDK InvenSense |
| Motion channels | Three accelerometer and three gyroscope axes | TDK InvenSense |
| Host interface | I²C | TDK InvenSense |
Compatibility and practice
MPU-6050 uses I²C. Check the supply and I²C pull-up voltage on the carrier.
Related components
Sources and datasheets
- MPU-6050 specifications · TDK InvenSense