Skip to Content
Circuitera

Single-phase bridge rectifier

Identify the two AC inputs and positive and negative outputs, and understand why a bridge’s output voltage drops under load.

Single-phase bridge rectifier photograph
3PM4 diode bridge, IPRS Baneasa 1988 (01).jpg by 155LA3 · CC BY 4.0. Resized and encoded as WebP without cropping.

Current path

A different pair of diodes carries current on each AC half-cycle. Both paths deliver current through the load in the same direction. Two forward diode drops therefore contribute to loss through the bridge.

Source: Vishay

Matching the terminals

Find the two input markings and DC plus and minus on the body or pin diagram. Package variants arrange those terminals differently. The photographed 3PM4 illustrates the package concept; the Vishay sheet covers a different representative series.

Source: Vishay

Sizing and smoothing

Check forward current, reverse voltage and surge limits against the design. A smoothing capacitor can increase peak charging current and retain voltage after power is removed.

Source: Vishay

Specifications

ParameterValue or conditionSource
Internal circuitFour diodes arranged as a single-phase bridgeVishay
Terminal functionsTwo AC inputs and one positive and one negative outputVishay

Compatibility and practice

For bench practice use an isolated low-voltage AC source and verify the terminals on the package.

Sources and datasheets