NE555 timer
Learn how the NE555’s trigger, threshold and discharge pins work together in a timer or oscillator, and check its operating supply.

How it works
Two internal comparators observe the timing voltage. With the control voltage at its standard setting, the trigger threshold is around one-third of the supply and the upper threshold is around two-thirds. A latch controls the output and discharge transistor.
Pinout
The 8-pin device uses GND (1), TRIG (2), OUT (3), RESET (4), CONT (5), THRES (6), DISCH (7) and VCC (8). Read it from the top using the notch or dot as the orientation mark.
Timing examples
In a one-shot, triggering starts a pulse while an external resistor charges the timing capacitor. An astable connection makes the capacitor charge and discharge repeatedly. Tie RESET high if unused and keep the timing node away from loads that would alter the charge time.
Specifications
| Parameter | Value or condition | Source |
|---|---|---|
| Recommended operating supply | 4.5–16 V for TI NE555 | Texas Instruments |
| Typical RC comparator thresholds | Approximately ⅓ and ⅔ of the supply with control voltage left at its standard level | Texas Instruments |
Compatibility and practice
The TI NE555 uses a recommended supply starting at 4.5 V; use a suitable CMOS timer for lower supplies.
Related components
Sources and datasheets
- xx555 precision timers datasheet · Texas Instruments